D-60 (Dual Output)
Features & Specifications
Universal AC input/Full range
Protection:Short circuit / over load
Approval:CE
100% full load burn-in test
High reliability,low cost
2 years warranty
| INDEX TYPE |
D-60-P1 |
D-60-P2 |
| DC VOLTAGE |
5V |
12V |
5V |
24V |
| VOLTAGE TOLERANCE |
±2% |
±6% |
±2% |
±5% |
| RATED CURRENT |
6A |
3A |
3A |
1.8A |
| CURRENT RANGE |
0.3-6A |
0.2-4A |
0.3-6A |
0.2-2.2A |
| RIPPLE&NOISE (MAX.) |
75mVp-p |
150mVp-p |
75mVp-p |
150mVp-p |
| LINE REGULATION |
±0.5% |
±1% |
±0.5% |
±0.5% |
| LOAD REGULATION |
±0.5% |
±4% |
±0.5% |
±4% |
| RATED POWER |
56W |
58W |
| EFFICIENCY |
73% |
76% |
| VOLTAGE ADJ.RANGE |
+10,-5% |
+10,-5% |
| VOLTAGE RANGE |
85~264VAC 47~63Hz |
| AC CURRENT |
2A/115V 1A/230V |
| INRUSH CURRENT (MAX.) |
cold inrushed current 30A/115V 60A/230V |
| LEAKAGE CURRENT |
<1A/240VAC |
| OVERLOAD PROTECTION |
105-150% Type :Current limitation auto recovery |
| OVERVOLTAGE PROTECTION |
5.75~6.73V |
| OVER TEMP. PROTECTION |
| TEMP.COEFFICIENT |
±0.03%℃(0~50℃) ON+5V OUTPUT |
| SETUP.RISE,HOLD TIME |
800ms,50ms,10ms/115VAC 300ms,50ms,80ms/230VAC |
| VIBRATION |
10~500Hz,2G 10min/1cycle,60min,each axes |
| WITHSTAND VOLTAGE |
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC |
| ISOLATED RESISTOR |
I/P-O/P,I/P-FG,O/P-FG:500VDC/100MΩ |
| WORKING TEMP.HUMIDITY |
-10℃~+60℃,20%~90%RH |
| STORAGE TEMP.HUMIDITY |
-20℃~+85℃,10%~95%RH |
| DIMENSION |
159*97*38mm |
| WEIGHT |
0.55Kgs |
| COOLING METHOD |
| SAFETY STANDARDS |
UL1012 TUV(En55022) CLASS B, IEC801-2,3,4 IEC555-5 |
| EMC |
FCC part15.conduction |
Note:
1.All parameters NOT specially mentioned are measured at 230VAC input ,rated load and 25 of ambient temperature.
2.Tolerance:includes set up tolerance, line regulation and load regulation
3.Ripple&noise are measured at 20MHZ of bandwidth by using a 12 twisted pair-wire terminated with a 0.1uf&47uf parallel capacitor.
4.line regulation :min&max voltage of the rated load.
5.load regulation: load from 0 to 100%.